PT2000 Series Pressure Transmitters

Brand: Turck, Inc

Turck introduces the PT2000 line of pressure transmitters, which offers a welded stainless steel measuring cell for increased durability and increased chemical compatibility. These transmitters have no elastomer seals and all wetted materials are 316L stainless steel, providing an ideal solution for water pumping, hydraulic, and refrigeration applications.

The transmitter housing is gel filled, eliminating problems caused by condensation in applications with a wide range of temperatures, such as pumping ground water. Additionally, the housing is more compact than existing solutions, suiting it for applications with space constraints. The transmitter is capable of handling pressures up to 1000 bar as well as process media up to 135 °C.

Equipped with a standard M12 connector that is available in multiple wiring configurations, the PT2000 is easily integrated into existing applications. The new pressure transmitter is also available with process connections such as NPT, BSPP and SAE, which are commonly used in North American hydraulic applications.

The PT2000 line gives customers a robust, stainless steel solution in a compact, economical package,” explained Rich Tallant, Product Manager for sensors.

The PT2000 offers multiple output signals to provide additional options for customers and allowing the offering to adapt to users’ existing control circuitry; 4-20 mA, 0-10 V, ratiometric, 1-6 V, and 0-5 V. Additionally, it carries an IP67 rating, and has an operating temperature range of -40 to +135 °C.
Features
  • 316 welded stainless steel measuring element
  • 316 stainless steel housing with Polyarylamide 50% GF electrical connector
  • NPT, G (BSPP), and SAE-ORB process connections
  • Gel filled housing
  • Ranges up to 1000 Bar

Specifications

Brand

Over Pressure

  • ≤ 6 bar = 5X full scale (max 1500 Bar)
  • > 6 bar = 3X full scale (max 1500 Bar)

Burst Pressure

  • ≤ 6 bar = 10X full scale (max 2500 Bar)
  • > 6 bar = 6X full scale (max 2500 Bar)

Analog Accuracy LHR

  • ± 0.30 % full scale

Temperature Coefficient

  • ± 0.20 % of measuring range per 10° C

Operating Voltage

  • I2 & I3: 7 - 33 VDC
  • IX: 10-30 VDC
  • U1: 12 - 33 VDC
  • U2: 8 - 33 VDC
  • U6: 5 VDC regulated

Current Consumption

  • I2: ≤ 23 mA
  • U1,2,3,6: ≤ 7 mA

Response Time

  • < 2 ms

ATEX Approval

  • IX: II 1/2 GD: Ex ia IIC T4 Ga/Gb,  Ex ia IIIC T125 °C Da/Db

Ambient Temperature

  • -30° to 85° C

Housing Material

  • 316 stainless steel / Polyarylamide 50 % GF

Wetted Materials

  • 316 stainless steel (≤ 60 bar 430 stainless steel)

Protection Type

  • IP67

Shock Resistance

  • 40 g for 6 ms, 1000x all 3 directions per IEC 68-2-29

Vibration Resistance

  • 20 g, 15 - 2000 Hz, 15 - 25 Hz with amplitude μ 15 mm,1 Octave/min. all 3 directions, 50 constant load per IEC 68-2-6

show more