Brand: Kubler Group

The multiturn encoders Sendix 5868 with PROFINET interface and optical sensor technology are ideal for use in all applications with a PROFINET interface. 

The encoder supports the isochronous (IRT) mode and is therefore ideal for real-time applications. Easy start-up thanks to the "Ezturn for PROFINET" software supplied with the encoder.
Features
  • Reliable
    • Ideally suited for all PROFINET applications thanks to the use of encoder profile 4.1
    • Perfect for use in harsh outdoor environments, as a result of IP67 protection and rugged housing construction
  • Flexible
    • IRT-Mode
    • Cycle time ≤1 Millisecond
    • Firmware updater allows for easy expansion of characteristics without having to disassemble the encoder.
    • Faster, easier error-free connection thanks to M12 connectors

Specifications

Brand

Approvals & Certifications

  • CE Compliant: EMC Guideline 2004/108/EC
  • Ex Approval for Hazardous Area: Zone 2 & 22
  • RoHS Compliant: Guideline 2011/65/EU
  • UL (C,US): File 224618

Capacity

  • Axial Load Capacity of Shaft: 40 N
  • Radial Load Capacity of Shaft: 80 N

Communication

  • PROFINET IO

Configuration

  • Ezturn Software for PROFINET

Consumption

  • Power Consumption (No Load): 200 mA - Max.

Cycling Rate

  • ≤ 1 millisecond

Diameter

  • Clamping & Synchro Flange: 2.28” (58 mm)
  • Square Flange: 2.5” (63.5 mm)

Display

  • LED Display

Electrical Connectors

  • 3 x M12 Connector, 4-Pin

Enclosure, Body Material

  • Zinc Die Cast Housing

Environmental Protection

  • IP65
  • IP67

Flange Material

  • Aluminum

Flange Type - Other

  • Clamping Flange
  • Square Flange
  • Synchro Flange

Operating Temperature

  • -40° to 85° C (-40° to 185° F)

Power Supply

  • 10-30 Vdc

Resolution

  • Multiturn Resolution: Max.
  • Singleturn Resolution: 1 to 65,535 (16-bits), Scaleable
  • Total Resolution: 1 to 268.435.456 (28-bits), Scaleable

Reverse Polarity Protection

  • Yes

Shaft Material

  • Stainless Steel

Shock

  • Shock Resistance According to EN 60068-2-27: 2,500 m/sec², 6 milliseconds

Speed

  • Maximum

Torque

  • Starting Torque (IP67): < 0.05 Nm
  • Starting Torque: < 0.01 Nm

Vibration

  • Vibration Resistance According to EN 60068-2-6: 100 m/sec², 55 to 2,000 Hz
show more